Zero Order and Area Under Curve Spectrophotometric methods for determination of Omeprazole Capsules in Pharmaceutical Formulation

Santosh Balaso Jadhav, Rekha Kharat, Farhat Mujawar Pirjade, Dilshadbe Tamboli

Abstract


Simple, fast and reliable spectrophotometric methods were developed for determination of Omeprazole in bulk and pharmaceutical dosage forms. The solutions of standard and the sample were prepared in Methanol. The quantitative determination of the drug was carried out using the zero order derivative values measured at 238 nm and the area under the curve method values measured at 300-305 nm (n=2). Calibration graphs constructed at their wavelengths of determination were linear in the concentration range of Omeprazole using 2-10μg/.ml (r²=0.9985 and r²=0.9959) for zero order and area under the curve spectrophotometric method. All the proposed methods have been extensively validated as per ICH guidelines. There was no significant difference between the performance of the proposed methods regarding the mean values and standard deviations. Developed spectrophotometric methods in this study are simple, accurate, precise and sensitive to assay of Omeprazole in tablets.


Keywords


Omeprazole, UV visible spectrophotometry, AUC, Method Validation

Full Text:

PDF

References


Stenhoff H, Blomqvist A, Lagerstrom PO. J Chromatography B 1999; 734: 191–201.

The United States Pharmacopoeia, Asian edition, Rockville, MD: USP Convention Rockville, MD, USP Convention Inc, 2007, p.2796-2798.

Indian Pharmacopoeia, Volume II, Published by the controller of Publication, Delhi, 2007, 1473-1475.

Dubuc MC, Hamel C, Caubet MS, Brazier JL. J LiqChromatogr& Related Tech 2001; 24: 1161- 1169.

El-Sherif ZA, Mohamed AO, El-Bardicy MG, El-Tarras MF. Chem& Pharm Bull 2006; 54: 6814.

Murakami FS, Cruz AP, Pereira RN, Valente BR, Silva MAS. J LiqChromatogr&Related Tech 2007; 30: 113-121.

Sivasubramanian L, Anilkumar V. Indian J Pharm Sci 2007; 69: 674-676.

Sluggett GW, Stong JD, Adams JH, Zhao Z. J Pharm Biomed Anal 2001; 25: 357-61.

Junior IJSde, Sartor JP, Rosa PCP, VeredasVde, Júnior AGB, Santana CC. J Chromatogr A 2007; 1162: 97-102.

Ribani M, Collins CH, and Bottoli CBG. J Chromatogr A 2007; 1156: 201-205.

Petsalo A, Turpeinen M, Pelkonen O, Tolonen A. J Chromatogr A 2008; 1215: 107-115.

Panigrahi D, Sharma R. ActaChromatog 2008; 20: 439-450.

Kobayashi K., Chiba K., Sohn D.S, Kato I., Ishizaki T. J Chromatogr B 1992; 579:299-305.

Macek J, Ptacek P, Klima J. J Chromatography B 1997; 689:239-243.

Raval PB, Puranik M, Wadher SJ, Yeole PG. Indian J of Pharm Sci 2008; 70: 386-390. International Conference on Harmonization (ICH) of Technical Requirements for the registration of Pharmaceuticals for Human use, Validation of Analytical Procedures Methodology; ICH-Q2(R1), Geneva, 1-8, 1996.




DOI: http://dx.doi.org/10.7439/ijasr.v1i2.1854

Article Metrics

Metrics Loading ...

Metrics powered by PLOS ALM

Refbacks

  • There are currently no refbacks.


Copyright (c) 2015 International Journal of Advances in Scientific Research

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.